Tungsten Import Connector 2026.3 Update 1
Build date: July 24, 2026
© 2026 Tungsten Automation. All rights reserved.
Use is subject to license terms.
Introduction
Install Tungsten Import Connector 2026.3.1 to resolve the issues listed below.
Note: To install Tungsten Import Connector 2026.3.1 successfully, an existing full installation of Tungsten Import Connector 2026.3 is required.
If you need to perform a full product installation, see the Tungsten Import Connector Installation Help for instructions.
Issues resolved in this update
| ID | Issue | Solution |
|---|---|---|
| 2252422 | The EML to PDF conversion failed when the source EML file contained a PDF portfolio attachment. | Improved the EML file conversions involving PDF portfolio attachments. |
| 2252003 | A timeout error occurred while retrieving the user list from the RightFax server, which contained approximately 8,000 users. |
Increased the timeout to retrieve large user lists. |
| 2251418, 2251196, 2251192 | The following issues were observed during the EML to PDF conversion using MS Graph:
|
Enhanced the functionality to preserve the original orientation of the .mht files and retain fully embedded images within the email body. |
| 2240212 | The watched folder test connection failed with the following error: "Connection to folder \\filserver4\data\kofax\Dev\UDK\NGDP\Leverancer\Blanketmotor\Forsendelser on ATP-60UKICKFX01.prod.atp.local cannot be established. GetNamedSecurityInfoW: on folder \\filserver4\data failed, error=0" |
The test connection is now successful. |
Security issues resolved in this update
| ID | Issue | Solution |
|---|---|---|
| 2255188 | OpenSSL versions 3.0, 3.3, 3.4, 3.5, and 3.6 were affected by the security vulnerability CVE-2025-15467. | Upgraded to the latest version of OpenSSL. |
| 2248039 | ImageMagick 7.1.2-13 contained a security vulnerability. |
Upgraded ImageMagick to version 7.1.2-25. |
Applies to
Apply this update to Import Connector 2026.3.
Files included
This update includes the following files.
| File name | Version |
|---|---|
| KCPlugin-26.3.1.297.msp | 26.3.1.297 |
| KCPlugin-26.3.1.297.bat | NA |
| MC-26.3.1.297.msp | 26.3.1.297 |
| MC-26.3.1.297.bat | NA |
| ReadMe-Tungsten Import Connector 2026.3.1.htm | NA |
Install this update
For best results, install the update during off-peak processing hours.
- Verify that the following applications/services are not running.
- TC Plug-In application and service
- Message Connector Service
- Extract the contents of the .zip file on the computer where Tungsten Import Connector is installed.
Run MC-26.3.1.297.bat and follow the on-screen instructions.
Note: To update a single instance or multiple instances of Message Connector in silent mode:
- Open Command Prompt and navigate to the directory containing the update.
- Execute the following commands:
- Instance 1: msiexec /update MC-26.3.1.297.msp KOFAXPRODUCTVERSION=2026.3.1.297 /qb /l*vx MC-2026.3.1.297-Inst1.log /n {151DB290-385D-4495-813A-DEAC6AB8FDEC}
- Instance 2: msiexec /update MC-26.3.1.297.msp KOFAXPRODUCTVERSION=2026.3.1.297 /qb /l*vx MC-2026.3.1.297-Inst2.log /n {7281CCBD-3721-42E1-81E7-270BBE7E94FE}
- Instance 3: msiexec /update MC-26.3.1.297.msp KOFAXPRODUCTVERSION=2026.3.1.297 /qb /l*vx MC-2026.3.1.297-Inst3.log /n {88AD3B67-7BA1-4AB9-BE00-70B3876990BB}
On the computers where TC Plug-In is installed:
- Close Tungsten Capture Administration.
- Run KCPlugin-26.3.1.297.bat and follow the on-screen instructions.
- Restart any applications or services that were stopped prior to installing the update.
- Verify that the TC Plug-In and the Message Connector services are running.
Remove this update
For best results, remove the update during off-peak processing hours.
- Verify that the following applications/services are not running.
- TC Plug-In application and service
- Message Connector Service
- To uninstall Message Connector:
- In Control Panel, select Programs and Features > View installed updates.
- On the list of updates, in the Name column, select MC fix pack MC-26.3.1.297.
- Right-click and select Uninstall.
- To uninstall TC Plug-In:
You cannot uninstall the update for TC Plug-In. You must uninstall Tungsten Import Connector and install it again without the update.
- Restart any applications or services that were stopped prior to removing the update.