Issues resolved in this update

ID Issue Solution
2252422 The EML to PDF conversion failed when the source EML file contained a PDF portfolio attachment. Improved the EML file conversions involving PDF portfolio attachments.
2252003

A timeout error occurred while retrieving the user list from the RightFax server, which contained approximately 8,000 users.

Increased the timeout to retrieve large user lists.

2251418, 2251196, 2251192

The following issues were observed during the EML to PDF conversion using MS Graph:

  • The attached .mht file appeared rotated by 90 degrees.
  • The images embedded in the email body were partially cut off.

Enhanced the functionality to preserve the original orientation of the .mht files and retain fully embedded images within the email body.

2240212

The watched folder test connection failed with the following error:

"Connection to folder \\filserver4\data\kofax\Dev\UDK\NGDP\Leverancer\Blanketmotor\Forsendelser on ATP-60UKICKFX01.prod.atp.local cannot be established. GetNamedSecurityInfoW: on folder \\filserver4\data failed, error=0"

The test connection is now successful.

Security issues resolved in this update

ID Issue Solution
2255188 OpenSSL versions 3.0, 3.3, 3.4, 3.5, and 3.6 were affected by the security vulnerability CVE-2025-15467. Upgraded to the latest version of OpenSSL.
2248039

ImageMagick 7.1.2-13 contained a security vulnerability.

Upgraded ImageMagick to version 7.1.2-25.

Applies to

Apply this update to Import Connector 2026.3.

Files included

This update includes the following files.

File name Version
KCPlugin-26.3.1.297.msp 26.3.1.297
KCPlugin-26.3.1.297.bat NA
MC-26.3.1.297.msp 26.3.1.297
MC-26.3.1.297.bat NA
ReadMe-Tungsten Import Connector 2026.3.1.htm NA

Install this update

For best results, install the update during off-peak processing hours.

  1. Verify that the following applications/services are not running.
    • TC Plug-In application and service
    • Message Connector Service
  2. Extract the contents of the .zip file on the computer where Tungsten Import Connector is installed.
  3. Run MC-26.3.1.297.bat and follow the on-screen instructions.

    Note: To update a single instance or multiple instances of Message Connector in silent mode:

    1. Open Command Prompt and navigate to the directory containing the update.
    2. Execute the following commands:
      • Instance 1: msiexec /update MC-26.3.1.297.msp KOFAXPRODUCTVERSION=2026.3.1.297 /qb /l*vx MC-2026.3.1.297-Inst1.log /n {151DB290-385D-4495-813A-DEAC6AB8FDEC}
      • Instance 2: msiexec /update MC-26.3.1.297.msp KOFAXPRODUCTVERSION=2026.3.1.297 /qb /l*vx MC-2026.3.1.297-Inst2.log /n {7281CCBD-3721-42E1-81E7-270BBE7E94FE}
      • Instance 3: msiexec /update MC-26.3.1.297.msp KOFAXPRODUCTVERSION=2026.3.1.297 /qb /l*vx MC-2026.3.1.297-Inst3.log /n {88AD3B67-7BA1-4AB9-BE00-70B3876990BB}

  4. On the computers where TC Plug-In is installed:

    1. Close Tungsten Capture Administration.
    2. Run KCPlugin-26.3.1.297.bat and follow the on-screen instructions.
  5. Restart any applications or services that were stopped prior to installing the update.
  6. Verify that the TC Plug-In and the Message Connector services are running.

Remove this update

For best results, remove the update during off-peak processing hours.

  1. Verify that the following applications/services are not running.
    • TC Plug-In application and service
    • Message Connector Service
  2. To uninstall Message Connector:
    1. In Control Panel, select Programs and Features > View installed updates.
    2. On the list of updates, in the Name column, select MC fix pack MC-26.3.1.297.
    3. Right-click and select Uninstall.
  3. To uninstall TC Plug-In:

    You cannot uninstall the update for TC Plug-In. You must uninstall Tungsten Import Connector and install it again without the update.

  4. Restart any applications or services that were stopped prior to removing the update.