RCF application
This Process Monitor plug-in is used to display capture-specific data
such as:
The data cannot be changed here but only viewed.
Access the RCF application from the
or view of the Process
Monitor plug-in (XBOUND Help
topic) by clicking first the button
and then the button:

Note: The xboundDocumentFunctionOcf.dll
file must be available in the XBOUND program directory in order to open
the RCF application.
The RCF display consists of two panes: In the left pane, the read and
classification results are displayed in a hierarchical list. If you click
a field or extraction result, the source image is displayed on the right,
with the item highlighted on it.
Different data is available on the various tabs. Which data is displayed
depends on how your system is set up.
tab: Shows all document
fields with their information. Expand a field entry to show field
alternatives, and expand field alternatives to show field characters.
(
More
information about the available data.)
tab: Shows all table
cells. Expand a table cell entry to show cell alternatives, and expand
cell alternatives to show cell characters. (
More information
about the available data.)
Table cell information
| Table name. |
| Table row. |
| Column name. |
| The cell's data type. |
| Cell content. |
| Field valid status: |
| Indicates whether the user accepted
the field by pressing
in Verification. |
| Indicates that the user accepted the field content despite errors. |
| Indicates that the field has been displayed in Verification
and that it was in focus there at least once. |
| User-defined value. |
| Read zone in millimeters. X: horizontal start position; Y: vertical
start position; W: width; H: height. |
| Read zone n pixels. X: horizontal start position; Y: vertical start
position; W: width; H: height. |
| Number of cell alternatives.
|
Cell alternatives
| This alternative corresponds
to the current field value. |
| Potential cell value. |
| Confidence of the extracted value: |
| A value between 0 and 1, which represents the certainty of the OCR component.
These values are used very differently by different OCR components. Please
use the instead. |
| The
component that was used. |
| Read zone in millimeters. X: horizontal start position; Y: vertical
start position; W: width; H: height. |
| Read zone n pixels. X: horizontal start position; Y: vertical start
position; W: width; H: height. |
Characters
| Character. |
| Confidence of the extracted value: |
| A value between 0 and 1, which represents the certainty of the OCR component.
These values are used very differently by different OCR components. Please
use the instead. |
| The OCR component that was used.
|
| Read zone in millimeters. X: horizontal start position; Y: vertical
start position; W: width; H: height. |
| Read zone n pixels. X: horizontal start position; Y: vertical start
position; W: width; H: height. |
tab: This tab shows
all read results grouped by
components. Expand a result to display information about recognized
lines, words, and characters. (
More information about
the available data.)
OCR components/images
| The
component. |
| The
on which OCR was performed. |
Lines
| Line result. |
| Read zone in millimeters. X: horizontal start position; Y: vertical
start position; W: width; H: height. |
| Read zone n pixels. X: horizontal start position; Y: vertical start
position; W: width; H: height. |
Words
| Word value. |
| A value between 0 and 1, which represents the certainty of the OCR component.
These values are used very differently by different OCR components. Please
use the instead. |
| Number of word characters. |
| Read zone in millimeters. X: horizontal start position; Y: vertical
start position; W: width; H: height. |
| Read zone n pixels. X: horizontal start position; Y: vertical start
position; W: width; H: height. |
Characters
| Character |
| Confidence of the extracted value: |
| A value between 0 and 1, which represents the certainty of the OCR component.
These values are used very differently by different OCR components. Please
use the instead. |
| The OCR component that was used.
|
| Read zone in millimeters. X: horizontal start position; Y: vertical
start position; W: width; H: height. |
| Read zone n pixels. X: horizontal start position; Y: vertical start
position; W: width; H: height. |
tab:
Shows all classification results for documents and images. Expand
an entry to display document type options. (
More information
about the available data.)
Classification results for documents (currently
used only with )
| The document type recognized
by the classification engine. This must not be the same
as the XBOUND document type. |
| A value between 0 and 1, which
states the certainty of the classification component.
A value of 1 indicates a 100% certain classification
result, whereas 0 indicates a highly uncertain classification
result. |
| Confidence of classification:
: certain. :
suggested value. : uncertain.
|
| Confidence of the separation: |
Classification results for images
| Classification component. |
| The on
which classification was performed. |
Document type options
| If selected, the document type
corresponds to current document type. |
| Document type name. |
| A value between 0 and 1, which
states the certainty of the classification component.
A value of 1 indicates a 100% certain classification
result, whereas 0 indicates a highly uncertain classification
result. |
| The classification component
that was used. |
© 2018 Kofax, Inc. All rights reserved. | Terms of Use