Trace Settings tab
Use this tab to configure log files and traces.
Single Process: If selected, all components of the application are running in the same process.
Trace Level: General trace level:
-
0 = Off
-
10 = Very rare tracing that happens only during initialization / startup.
-
20 = Low trace data per document. Less trace output with productive systems.
-
40 = More intense tracing. Productive use is possible but trace files can be large.
-
60 = Restricted performance for productive use (max. 10 channels recommended).
-
100 = Extensive tracing for troubleshooting. Operating multiple channels can fail.
-
More than 100: Reserved for third level support.
Message Trace Size: Message size limit in bytes to trace traffic between components:
-
0 = Off
-
1 = Single line per message
-
More than 1 = Size limit in bytes
Trace MIME Messages: Select to store received email messages in the same folder as the Message Connector log files.
OpenH323 Trace Level: Open H323 library trace level in the range of 0 to 255; 0 = off, higher values give a more detailed trace.
BtrTraceLevel: Enable binary trace files for fax calls.
BtrTraceFiles: Number of binary trace files.
BtrTraceMaxFileSize: Maximum file size of binary trace files in kilobytes.
Trace Location: Type the drive and path of the trace location.
Size of Trace File: Maximum size of trace files in KB.
Number of Trace Files: Maximum number of generated trace files.
Append Trace: Select to append to existing traces after application is restarted.
Keep Blobs: Define how long the binary large object files are preserved (for troubleshooting).