Trace Settings tab
Use this tab to configure log files and traces.
- Trace level
- Specify the general trace level. General trace levels include.
Value
Description
0
Off
10
Very rare tracing that happens only during initialization / startup.
20
Low trace data per document. Less trace output with productive systems.
40
More intense tracing. Productive use is possible but trace files can be large.
60
Restricted performance for productive use (max. 10 channels recommended).
100
Extensive tracing for troubleshooting. Operating multiple channels can fail.
More than 100
Reserved for third level support.
- Message trace size
- Specify the message size limit (in bytes) to trace traffic between components.
Value
Description
0
Off
1
Single line per message
More than 1
Size limit in bytes
- Trace location
- Type the drive and path of the trace location.
- Size of trace files
- Specify the maximum size of trace files in KB.
- Number of trace files
- Specify the maximum number of generated trace files. Once the number of trace files are equal to the value specified here, any new trace file overwrites the existing, starting from the oldest.
- Append trace
- Select to append to existing traces after application is restarted.
- Keep blobs
- Define how long the binary large object files are preserved (for troubleshooting).