Configure an Advanced Table Locator
Use the procedure in this topic to configure an Advanced Table Locator.
Before you can configure an Advanced Table Locator verify that the following steps are complete:
-
Open the
Advanced Table Locator
Properties.
The properties for the Advanced Table Locator are displayed.
-
Configure the following settings.
Setting
Description
Table Model
Select a table model from the list of existing table models.
If there is not a suitable table model, select Table Models to open the Project Settings - Tables tab where you can configure a new table model and its columns.
Filter tables
Define how to handle multiple detected tables in a document with the same table model by selecting one of the following values:
- The first table:
-
When selected, the first table in the document with this table model is used. (Default: Selected)
- The last table:
-
When selected, the last table on the document with this table model is used.
- The best table:
-
When selected, the table with the highest confidence is used.
- Concatenate all tables with confidence above:
-
When selected, all detected tables with this table model and that have a confidence above the configured level, are joined together into a single table. (Default: 70%)
Set the confidence level by adjusting the slider or entering a value into the % field.
-
In the
Document pane, select the
Test Set that contains your test documents.
The documents in the Test Set are listed in the Document Viewer.
-
Select one or more of the test documents, and select
Train for Table Extraction from the
Document Viewer menu.
The selected test document is added to the Table Extraction Set.
-
Select the
Table Extraction Set.
A list of documents in this document set are displayed. Documents already configured for table training are marked with Include for Training. Documents that still require table training are marked with Exclude from Training
-
Double-click on a document marked with
Exclude from Training.
The Table Training window is displayed and an image of the selected training document is displayed, along with all detected tables in that document. Perform the following steps to configure this training document for table training:
-
In the
Table Training window, use the
Next Page and
Previous Page to view the tables on your document and select a table that contains the data
you are extracting.
The Assign Table Label window is displayed.
-
In the
Assign Table Label window, configure the following and select
OK.
Setting
Description
Select a table model as table label
Select a table model from the list of existing table models.
If the table model you need does not already exist, select Table Models to create a table model on-demand.
Select <None> to remove a label.
-
On the image, select the first column in your table.
The Assign Column Label window is displayed.
-
In the
Assign Column Label window, configure the following and click
OK.
Setting
Description
Assign column label for
Select a table model column from the list of existing columns in the table model.
If the column you need does not already exist in the selected table model, select Table Models to update or create a table model on-demand.
Select <None> to remove a column label.
- Repeat step 6d for all columns in the table.
-
Optional. Select
Next Page and
Previous Page to add table and column labels for additional documents.
- When all training documents have table training data, select from the menu to save the table training document.
The Table Training window is closed.
-
In the
Table Training window, use the
-
In the
Documents window, select
Save All Documents to save the changes to your
Table Extraction Set.
-
On the ribbon
Process tab, in the
Train group, select
Extraction & Table Extraction or its sub setting for
Table Extraction.
Your project is trained for advanced table extraction.
-
In the locator properties window, select
Test.
The Test tab is displayed with the results from the locator for each subfield. The fields are also highlighted on the document.
- Optional. Test again using other documents.
- Click Close to save the changes to the locator.
-
Assign a field to a locator manually or use the Create and Assign Fields button to create fields automatically.