Configure an existing zone

Use the procedure in this topic to modify a zone for an Advanced Zone Locator.

This is useful if the extraction of a zone for an Advanced Zone Locator is not performing as expected, you can make changes to it to improve your results.

Before you begin

Before you can modify a zone verify that you the following steps are complete:

Procedure
  1. Open the Advanced Zone Locator Properties icon Properties.
  2. On the General tab, double-click on the reference document.

    The Document Viewer (Zone Mode) window is displayed and all zones are highlighted yellow.

  3. Double-click on the zone you want to modify.

    The zone properties window is displayed along with the name of the zone.

  4. Optional. Rename the zone by editing the value in the Name field.
  5. On the General tab, configure the following settings.

    Setting

    Description

    Position

    For each of the position settings, tweak the values to ensure the entire text is enclosed within the zone parameters.

    Left:

    Adjust the left margin of the zone by increasing or decreasing this value.

    Top:

    Adjust the top margin of the zone by increasing or decreasing this value.

    Width:

    Adjust the width of the zone by increasing or decreasing this value.

    Height:

    Adjust the height of the zone by increasing or decreasing this value.

    Page:

    Select the page that contains the zone.

    If there is even a slight skew or offset in some documents, a tight zone border may result in failed extraction. Test several times to ensure there is enough buffer space for possible discrepancies in different documents.

    Rotation

    If enabled, this group enables you to rotate a zone in 90° increments. Use this setting is the contents of a zone are rotated and cannot be extracted by default. For example, some forms print unique identification marks down the margins of the page. In order to successfully extract those numbers, the zone needs to be rotated 90°. (Default: 0°)

    The rotation setting is disabled for OMR zones and OMR group zones.

    Dynamic Zone Adjustment

    Select whether to use dynamic zone adjustment for your zone. This is helpful if your documents have slight variations in layout. The possible settings include:

    Left:

    Adjusts the left margin of the zone automatically.

    Top:

    Adjusts the top margin of the zone automatically.

    Right:

    Adjusts the right margin of the zone automatically.

    Bottom:

    Adjusts the bottom margin of the zone automatically.

    Use the Test icon Test button to test the dynamic zone adjustment to ensure that it resizes appropriately.

    Blank Out Regions

    This setting lists any excluded portions of a zone so they are ignored during extraction.

    This setting is disabled if Dynamic Zone Adjustment is used.

    Use the Add icon Add, Delete icon Delete, and Delete icon Clear buttons to manage any blank out regions.

  6. For a text or OMR zone, select the Image Cleanup tab and configure the following settings.

    This tab is hidden for OMR group zones.

    Image Cleanup can use either a local profile specific for the zone or global profiles.

    Setting

    Description

    Enable

    Background Removal is available only if background information is created.

    Once enabled, select to enable background removal. You can augment the built-in background removal using image cleanup profiles.

    Profile

    Select a profile from the list for testing. These cleanup profiles can be set up in the Project Settings - Image Cleanup tab. You can also copy methods from other profiles.

    Properties icon Properties

    Opens the Image Cleanup window for the local profile.

    See Add image cleanup for a zone to configure a local cleanup profile.

    Copy

    Enables you to copy global image cleanup methods so they can be used locally without affecting any other zones using the global copy.

    Profiles

    Opens the Project Settings - Image Cleanup tab window.

    Test icon Test

    Test the selected profile against the image displayed at the top of the window.

  7. Select the Anchors tab and configure the following settings.

    This tab enables you to assign manual anchors to zones. These anchors override global registration results if the minimum number of anchors is recognized. You can map multiple zones to a single anchor, assign different anchors to different zones on the same page, and specify the required number of recognized anchors. A zone is valid if the required number of anchors are recognized. If fewer than the required number of anchors is recognized, the zone is invalid.

    Setting

    Description

    Available Anchors

    This table lists the name and type of anchors configured in this Advanced Zone Locator.

    Selected Anchors

    This table lists any anchors selected for this zone.

    Use the Assign subfield button and Unassign subfield button buttons to manage the Selected Anchors.

    Required number of recognized anchors

    Select the number of anchors that are required to make the zone valid. (Default: all)

  8. In addition, to the tab settings, configure the following settings that are available on all tabs.

    Setting

    Description

    Use PDF text if available

    Avoids running recognition for a PDF that has embedded text.

    Profile

    Select a profile from the list.

    Use the Properties icon Properties button to open the Profile Settings for the selected recognition profile.

    Select the Profiles button to open the Project Settings - Recognition tab where you can manage your recognition profiles.

    Recognition Test

    This displays the test results for the selected zone and its subfields.

    These test results only refer to the reference document. If you want to test the results for other documents, you need to test them in the locator properties.

  9. Select Close to close the zone properties window.
  10. Open several test documents that you did not use as sample documents.
  11. On the Advanced Zone Locator properties window, select the Test Results tab and then select Test icon Test.

    The detected subfields are displayed

  12. Tweak the settings for your zones until you have satisfactory extraction results.
  13. Select Close to close the locator properties window.
  14. Save the changes to your project.
Next steps