Configure simple field details
Use the procedure in this topic to configure simple field details.
The field details are displayed when a simple field
is selected in the
Project Tree.
Before you can configure simple field details, your project must have at least one simple field.
- Expand the Project Tree and select a class.
-
Optional. View the class contents if they are not
already displayed.
The hidden class contents are displayed.
-
Select a
simple field.
The field details are displayed.
-
Configure the following settings:
Setting
Description
General group
Field populated by
This setting determines how a field is populated during processing. It can be populated by a locator configured for this class or a fixed value. If you select <fixed value>, the Fixed field value field is available to enter the fixed value. (Default: none)
The Go to locator details link enables you to open the locator properties for the selected locator method so you can tweak the extraction settings for that particular locator. The correct locator is also selected in the Project Tree hierarchy. For inherited fields, the parent locator is displayed rather than the inherited read-only locator.
Field formatting method
Select an existing formatter from the list. The selected formatter is applied to this field after extraction.
If the value is set to anything other than <inherited>, select
Field Formatting Method to edit the formatter.
If you want to create a new formatter, select the Formatters button.
Always CAPITAL letters
Changes all field content to upper case. (Default: Selected)
Training group
Show in training dialog
Use this setting for a field that is mapped to a group locator subfield to determine whether the field is displayed for training on the Edit Document window or whether it is hidden and cannot be trained. By default this setting is always selected for fields mapped to a group locator. However, if fields are mapped to a non-group locator, this setting is disabled by default.
Monitor for automatic learning
Available only for trainable locator fields when online learning and Automatic training after Validation are enabled. Monitors a field for automatic training. (Default: Cleared)
If this field is incorrectly extracted and a user has to manually correct its physical coordinates, the document is flagged for online learning.
If a user corrects a field by changing its text, no field coordinates are provided, and as a result, that field does not qualify its document for automatic training. If however, the user updates a field and the field coordinates change, using either auto-complete or the lasso, the document is added to a dynamic knowledge base for automatic training.
Even if this setting is selected, it is not inherited by any child classes. This means that inherited fields are not automatically flagged for online learning.
Thresholds for Validation group
Minimum confidence for locator
A locator’s best alternative is assigned to the field when the minimum confidence reaches at least this value. (Default: 10%)
Minimum confidence for valid
A field is only marked as valid if the confidence of the best alternative is higher than this value. (Default: 80%)
Minimum distance to second best alternative
A field is considered to be valid only, if the distance between the best and the second best alternative of the assigned locator is greater than or equal to this value. (Default: 10%)
Reread Options group
This enables zone recognition for a field using a specialized recognition profile. For example, recognizing an amount using a numeric profile. As prerequisites, extraction needs to have a valid field location from a locator and a recognition profile. For rereading a zone is placed over the field result on the document to perform recognition again with the selected recognition profile. The result of this zone recognizer replaces the original result if the minimum reread confidence is reached.
You cannot select a Tungsten Clarity zone profile for reread.
Recognition profile
By default, rereading is not performed. To enable this setting, select a profile from the list. This profile is used if it is necessary to reread the document.
If a profile is selected, select
Recognition Profile to edit the selected profile. Alternatively, select the
Recognition Profiles button to create a new profile.
In addition, the <FieldName>_AfterFieldReread script event is available to control what value is overwritten as field result.
Minimum confidence to accept reread result
A reread value is only accepted if the threshold value specified here is reached. (Default: 70%)
- Repeat the above steps for other fields.
- Save your project.