Unified Client for Ricoh Smart Operation Panel 1.1 actions reference

Actions that can be performed from the Device Registration Service for a Unified Client for Ricoh Smart Operation Panel 1.1 device. An action can be performed on a single device or on all devices in a group.

To perform an action, first select a device on the Device tab in the Device Registration Service web console. Then, in the box at the top of the Details pane, click an available action to perform on the device and click the run button . To perform an action on all devices in a group, first select the group folder on the Device tab, and then run the action.

Action Description

Install and Reboot

Installs the Unified Client for Ricoh Smart Operation Panel 1.1 on the device. This action first uninstalls any package already installed on the MFP, then installs the package associated with the device configuration, sets required SP mode, and then restarts the MFP. The reboot may take some time to complete.

Run the Configure and Reboot action after you complete this action.

If you expect to wake up the MFP from sleep mode via a card swipe, you must set this setting: Service > Screen Features > Screen Device Settings > Screen device always-connection Setting See System Configuration Settings

Configure and Reboot

Updates device configuration for the Unified Client for Ricoh Smart Operation Panel 1.1 package installed on the device and then restarts the MFP. This action must be run after you complete the Install and Reboot action.

The device will be rebooted two times when you run this action. The Action initially tries to set SP Mode settings to their default values and applies the new values, including whether to associate the Home key with the client, that have been specified in the Device settings. Warnings that settings were not configured indicates that the Action was unable to apply a setting, which you may choose to manually configure on the physical device.

Uninstall

Uninstalls the Unified Client for Ricoh Smart Operation Panel 1.1 on the device.

Reboot

Restarts the MFP.

Get device settings

Gets current SP Mode settings on the device. Running this Action logs SP Mode settings and their values to a properties file (with the .properties extension). The default path to these properties files is:

C:\Program Files\Nuance\Device Registration Service\Service\Plugins\RXOP-SOP\CLITools\output

The file name of each log includes the IP address of the device followed by an underscore (_) and a Universal Time (UT) date-time stamp (YYYYMMDDHHMMSS). For example:

10.56.59.31_20160802221258.properties
10.56.59.35_20160802221451.properties
10.56.59.35_20160805204754.properties

Each file first lists the day, month, date, local time, time zone and year followed by one property setting and value per line in the following format:

#
#Fri Aug 05 16:48:39 EDT 2016
adminAuthKey.file.tools=false
adminAuthKey.network.file=false
adminAuthKey.machine.general=false
adminAuthKey.file=false
userAuthDocumentServer=1
...

The actual settings and values listed in the file depend on the device.

Set device settings

This action sets configurations what were not completed by the Install and Reboot or Configure and Reboot actions.

Run this action if you get the following warning (return code = 0) on completion of either the Install and Reboot or the Configure and Reboot action:

Warning: Some configurations not set